Customization: | Available |
---|---|
Classification: | Biological Diagnostics |
Type: | Monitor |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Lead Mode | 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) |
Lead selection | I, II, III, avR, avL, avF, V |
Wave form | 2 ch |
Lead mode | 3 Leads ( R, L, F or RA, LA, LL) |
Lead selection | I, II, III, |
Wavef orm | 1 ch |
Gain | 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto |
HR and Alarm Range | Adult 15 ~ 300 bpm Neo/Ped 15 ~ 350 bpm |
Accuracy | ±1% or±1bpm, which is greater |
Resolution | 1 bpm |
Sensitivity | > 200 (uVp-p) |
Differential Input Impedance | > 5 MΩ |
CMRR | Monitor > 105 dB Operation > 105 dB Diagnosis > 85 dB |
Electrode offset potentia | ±300mV |
Leakage Current | < 10 uA |
Baseline Recovery | < 3 S After Defi. |
ECG Signal Range | ±8 m V ( Vp-p ) |
Bandwidth | Surgery 1 ~ 20 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz |
ECG Signal Range | ±8 m V ( Vp-p ) |
Bandwidth | Surgery 1 ~ 20 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz |
ARR Detecting | Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS, PNP, PNC,Alarm Available,Review Available |
Respiration | |
Method | Impedance between R-F(RA-LL) |
Differential Input Impedance | > 2.5 MΩ |
Measuring Impedance Range | 0.3~3 Ω |
Base line Impedance Range | 200~4 KΩ |
Bandwidth | 0.1~2.5Hz |
Resp. Rate | Measuring and Alarm Range Adult 0 ~ 120 Brpm Neo/Ped 0 ~ 150 Brpm Resolution 1 Brpm Accuracy ±2 Brpm |
Apnea Alarm | 10 ~ 40 S |
NIBP | |
Method | Oscillometric |
Mode | Manual, Auto, STAT |
Measuring Interval in AUTO Mode | 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min) |
Measuring Period in STAT Mode | 5 Min |
Pulse Rate Range | 40 ~ 240 bpm |
Alarm Type | SYS, DIA, MEAN |
Measuring and alarm range | Adult Mode SYS 40 ~ 270 mmHg DIA 10 ~ 215 mmHg MEAN 20 ~ 235 mmHg Pediatric Mode SYS 40 ~ 200 mmHg DIA 10 ~ 150 mmHg MEAN 20 ~ 165 mmHg Neonatal Mode SYS 40 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 110 mmHg |
Resolution | 1mmHg |
Accuracy | Maximum Mean error ±5mmHg Maximum Standard deviation ±8mmHg |
Overpressure Protection | Adult Mode 297±3 mmHg Pediatric Mode 240±3 mmHg Neonatal Mode 147±3 mmHg |
SpO2 | |
Measuring Range | 0 ~ 100 % |
Alarm Range | 0 ~ 100 % |
Resolution | 1 % |
Accuracy | 70% ~ 100% 2 % 0% ~ 69% unspecified |
Actualization intervalabout | 1 Sec. |
Alarm Delay | 10 Sec. |
Pulse Rate | Measuring and Alarm Range 20~300 bpm Resolution 1bpm Accuracy ±3bpm |
TEMP
|
|
Channe | 2 |
Measuring and Alarm Range | 0 ~ 50 ºC |
Resolution | 0.1 ºC |
Accuracy | ±0.2 ºC |
Actualization intervalabout | 1 Sec. |
Average Time Constant | < 10 Sec. |
IBP | |
Label | ART, PA, CVP, RAP, LAP, ICP, P1, P2 |
Measuring and alarm range | ART 0 ~ 300 mmHg PA -6 ~ 120 mmHg CVP/RAP/LAP/ICP-10 ~ 40 mmHg P1 / P2-10 ~ 300 mmHg |
Press Sensor |
Sensitivity 5 uV/V/mmHg Impedance 300-3000Ω |
Resolution | 1 mmHg |
Accuracy | ±2% or 1mmHg which is greater |
Actualization interval | about 1 secretary |